Water-based stage effects are powerful, but preparation can be time-consuming when the machines need to be fill water manually. For water & confetti stadium shot machines and other water effect machine setups, each unit must be filled with the right amount of water before the show starts. When several machines are spread across a venue, manual refilling quickly becomes slow, uneven, and difficult to monitor.
That is where an automatic water injection machine becomes useful. The MK-CN21 AquaFill is an intelligent water filling machine that is a preset-volume water filling system for professional stage and event crews, designed for professional event teams, rental companies, water shows, festivals, and fixed venues. It can refill up to 6 machines at the same time, and each outlet can be set with its own water volume, up to 15 L. Once the preset volume is reached, the outlet stops automatically.
This guide explains how to use a water refill machine like the MK-CN21 AquaFill, from preparation and pipe connection to control, menu settings, cleaning, and maintenance.
Step 1: Prepare Before Setup
Before connecting the machine, read the user manual and identify the main parts: water inlet, water outlets, quick connectors, display panel, pump power output socket, wired remote connector, and panel start button.
The MK-CN21 is supplied with waterproof connectors, but the water pump and water pipes need to be prepared by the user. Before the event, prepare a water pump with a power cable, enough pipes for all required outlets, a clean water source or tank, and the machines that need refilling.
Use clean water whenever possible, because sand, scale, or dirty water may affect pipes, valves, and flow meters over time. If the venue allows it, place the water source close to the AquaFill and the connected machines. Shorter pipe runs between AquaFill and water source help reduce bending, leakage, and pressure loss.
Place the machine on a flat surface. Keep it upright, leave at least 10 cm of ventilation space, and use a grounded power supply that matches AC 100-240 V, 50/60 Hz. Because the floor may become wet, remind the crew to prevent slipping.
Step 2: Connect the Outlet Pipes
Start with the output side. Connect the outlet quick connector and water pipe to the water outlet of the MK-CN21. Then connect the other end of the pipe to the water cannon, Water & Confetti Stadium Shot machine, or other water effect machine that needs automatic refilling. It’s better to mark your water pipe from #1 to #6 to prevent filling it incorrectly when you are filling multiple machines.
The AquaFill supports up to 6 outlets. For a small setup, connect only one or two machines. For a larger show, connect several units and manage each water line separately.
Check every connection before starting. Pipes should be firmly attached, not folded, blocked, or leaking. A bent pipe may slow filling and reduce the accuracy of the automatic water filling machine. If an outlet is not needed, set it to OFF in the Out Select menu.
Step 3: Connect the Water Pump and Inlet Pipe
Next, prepare the inlet side. The water pump’s power cable needs to splicing with the female power connector to get the electricity. Then connect the water pump to the inlet water pipe, connect the pipe to the inlet quick connector and attach it to the water inlet of the MK-CN21.
After the pump cable is safely connected, place the pump in the water tank or water source. Make sure the pump is properly used to pump the water up. It’s suggested to wrap a layer of filter mesh to ensure clean water flows into the machine. The MK-CN21 has a pump power output socket, marked with a yellow base on the panel, so the AquaFill can supply power to the pump during operation. Water injected speed depends on the pump power.
Step 4: Power On and Choose the Start Method
After all pipes are connected, connect the machine to power. The MK-CN21 provides three start methods for different working scenes.
The first method is panel operation. Press the start button to begin automatic water filling. The button light shows the status clearly: blue means standby, red means filling, and green means filling complete.
The second method is wired remote operation. Connect the wired control button to the white-base connector, then press the button to start filling. This is useful when the operator wants one-touch control nearby.
The third method is DMX control. In 1-channel mode, selected outlets can start together. In 6-channel mode, each channel corresponds to one outlet, allowing the operator to control each water line separately.
For DMX values, 0-10 means off, 11-199 means pause, and 200-255 means start. The console controls the trigger behavior, while the water volume is set on the AquaFill panel. In 6-channel mode, each channel has its matching water line. DMX values are same as 1-channel mode in each channel.
Step 5: Set the Water Volume for Each Outlet
Above are three types of methods to get the AquaFill to start filling water. If custom water volume is needed, this part should operate on the AquaFill’s panel. This is the main advantage of an automatic water injection machine over manual filling. On the display menu, enter Out Select. Press ENTER to choose outlets #1 to #6, use the up and down buttons to adjust the volume that the filling machine needs, then press ENTER to save and move to the next outlet.
Each outlet can be set from 0.0 L to 15.0 L, or set to OFF when that line is not needed. The volume changes in 0.5 L increments. For example, if every water cannon needs 6 L, set each active outlet to 6.0 L. If different machines need different amounts, one outlet can be set to 6.0 L, another to 8.0 L, and unused outlets can remain OFF.
During filling, the flow meter detects how much water passes through each line. When the preset amount is reached, the control system closes the valve automatically. This helps prevent overflow, reduce water waste, and keep multi-machine preparation more consistent before the show.
Step 6: Pre-Show Test Checklist
Before using the MK-CN21 AquaFill in a real show, run a short test instead of starting directly with the full effect sequence. A simple checklist helps the operator confirm that the water source, pipes, pump, outlet settings, and control method are all ready.
- Prepare enough clean water for the full setup, and make sure the water pump is properly inside the water tank or water source.
- Check that the pump cable is connected safely and that the pump power output socket is used correctly.
- Confirm that all water pipes are firmly connected to the quick connectors, with no bending, blockage, or leakage.
- Mark outlet pipes from #1 to #6 when filling multiple machines, so each pipe matches the correct water effect machine.
- Set the required water volume for each outlet in the Out Select menu, and set unused outlets to OFF.
- For DMX operation, confirm the DMX address, channel mode, and console values before filling.
- When filling, watch the panel light: blue for standby, red for filling, and green for filling complete.
- Check whether each connected machine receives the correct water amount and whether the outlet stops automatically after reaching the preset volume.
- Make sure the anti-slip measures are set. If there is water leakage or overflow, stop operation and adjust the pipe connection or volume setting before the show.
- After the test is complete, keep the setup stable and avoid moving the pipes unless the operator needs to reconnect the system.
Clean and Maintain the Machine
After the event, turn off the machine and disconnect power before removing pipes. Do not forget the pump’s power off. Disconnect all water lines, wipe the housing with a dry soft cloth, and store the unit in a dry and safe place. Do not use corrosive solvents or spray the machine directly with a high-pressure water gun.
For maintenance, regularly check the inlet, outlets, connectors, pipes, valves, and flow path. Remove dirt, scale, or impurities that may block water flow. If the machine will not be used for a long time, drain the remaining water from the pipes and internal water path, then store it in a dry and ventilated environment. Never store the machine with water inside in a cold environment since freezing may damage the valves, pipes, and flow meters.
Final Thoughts
The MK-CN21 AquaFill is more than a simple automatic water injection machine. For multi-machine water cannon setups, it gives crews a controlled and repeatable way to prepare water effects. With 6 independently managed outlets, preset filling volumes, automatic stop control, and DMX triggering, it helps reduce manual labor and improve show consistency.
If your project uses several stage effect machines needed water at the same time, learning how to use the AquaFill correctly can make setup faster, cleaner, and easier to manage. And if you’re planning your next event and want expert advice on equipment or materials, MOKA SFX is here to help.
📩 Connect with MOKA SFX
Want to pre-book a meeting or inquire about partnership opportunities?
📧 Email us at: info@mokasfx.com
🌐 Visit: www.mokasfx.com